Emergency treatment in midfacial fractures may be indicated in the following cases:
There are a variety of possible injuries affecting the globe that may require immediate ophthalmological treatment.
Pressure increase in the periorbital region due to retrobulbar hematoma can cause significant injury of the neurovascular structures with eventual loss of vision.
More details on retrobulbar hemmorage can be found here.
Note: Intraorbital bleeding in patients taking anticoagulation drugs requires special attention.
If a retrobulbar hematoma leads to a tense, proptotic globe, emergency decompression should be considered.
If a retrobulbar hematoma in the cooperative patient results in blindness, the time window to release the intraorbital pressure is limited to around one hour measured from the onset of blindness. This could mean urgent treatment under local anesthesia even in the emergency room prior to further imaging.
Transcutaneous transseptal incisions may help evacuate the hematoma and release the periorbital pressure. Alternative methods such as transconjunctival pressure release and/or lateral canthotomy and inferior cantholysis should be considered according to patient condition.
An exception may be where there is a pulsating exophthalmos which may be a sign of carotid-cavernous sinus fistula. A fistula of this nature requires appropriate preoperative imaging.
Note: retrobulbar hematoma is one of the most severe postoperative complications in patients who have undergone orbital trauma and/or surgery. This is one reason why the surgeon has to assess appropriate vision as soon as possible after injury and/or surgery.
Severe emphysema might significantly raise intraorbital pressure. If this compromises visual function or endangers the orbital contents, orbital decompression has to be considered. Drug protocol may include antibiotics and decongestive nasal drops.
Patients with sinus fractures in the periorbital region should not blow their nose in order to avoid additional emphysema due to acute pressure rise. Should sneezing occur, maintaining an open mouth posture minimizes increasing intranasal/intrasinus pressure.
Usually there is no need for emergency treatment in orbital floor/medial wall fractures unless there is severe ongoing hemorrhage in the orbital cavity, the paranasal, or nasal cavity.
In some younger patients, the so-called trap-door phenomenon can occur in which there is danger of necrosis of the entrapped rectus muscle within a few hours; immediate release of entrapped tissues is necessary.
Entrapment of eye muscle (especially in children)
The inferior rectus muscle is the most common ocular muscle to become entrapped with an orbital floor fracture (trap-door phenomenon) and this may not be visible on conventional x-rays. Entrapment requires urgent freeing of the muscle to prevent necrosis of the incarcerated muscle. Clinical examination should give evidence on impaired ocular muscle function. Entrapment is often associated with severe ocular pain on attempted range of motion, as well as nausea and vomiting, especially in children.
Note: In children, entrapment of the eye muscles is more common than in adults; this might be due to the higher elasticity of the bony structures (green-stick fractures are more common).
Special attention has to be paid to the posterior third of the orbit and the bony optic canal. Bony dislocations in these anatomical areas are more likely to be associated with traumatic optic nerve lesions.
Axial CT scan in the plane of the optic nerve shows multiple fractures of the lateral orbital wall and the greater wing of the sphenoid of the right side. Additional stretching of the right optic nerve is present. Fractures where fragments involve the posterior third of the orbit are susceptible to subsequent optic nerve disorders.
In case of severe bleeding the following options should be considered:
Note: following the emergency treatment, thorough diagnostic examination may be performed to find the source of bleeding:
AO Teaching video on fixation of a complex midface fracture
AO Teaching video on fixation of a zygomaticomaxillary fracture and an orbital floor fracture
Appropriate exposure of the orbit requires adequate visualization. This requires appropriate retraction of the soft tissues and lighting. Regular OR lights serve this purpose for the midorbit. The posterior orbit is better visualized using headlights or illuminated retractors.
Special malleable orbital retractors (straight or anatomically formed) are available with metric markings providing the surgeon with additional information regarding the extent of the fracture and the depth of the orbital dissection. Specific orbital retractors have been developed to improve orbital retraction and minimize prolapse of soft tissue during insertion of implants.
It is important to consider the unique contours of the orbital anatomy.
The key areas of the orbit involve mainly the posterior orbital floor and medial orbital wall which bulge towards the orbit resulting in an S-shape of the orbital floor in the posterior third (seen in a sagittal view along the axis of the optic nerve). Before bulging in the posterior third, the contour of the orbital floor slopes down directly behind the infraorbital rim before ascending towards the posterior aspect. This contour has to be restored in order to provide appropriate orbital volume and shape.
Inadequate/insufficient reconstruction of the orbital floor may lead to a hammock-shape contour. The latter can be observed in cases where resorbable implants were used or in cases where a thin wafer of silicone or porous polyethylene was used for reconstruction of large orbital wall defects.
The challenge of orbital floor repair is particular in the most posterior part and in the transition zone with the medial wall.
The transition zone between the medial orbital wall and the orbital floor is difficult to visualize intraoperatively. This becomes even more difficult to visualize in dissection further posteriorly.
Repair of the transition zone between medial orbital wall and floor is vital and determines the position of the orbital contents and the globe.
Coronal slice of a CT scan shows a non-affected left orbit with normal anatomy of the transition zone. (The arrow indicates the buttress of the transition zone between medial orbital wall and orbital floor).
Coronal slice of a postoperative CT scan taken after transconjunctival repair of the complete left medial orbital wall and orbital floor.
The overlying colored line in the medial wall and orbital floor area indicate the preoperative virtual planning that is superimposed on the mesh reconstructed area.
This x-ray shows the classic transition zone.
Reconstruction of the orbital floor has to respect the course of the infraorbital nerve in the orbital floor.
Depending on the amount and severity of dislocation around the course of the infraorbital nerve, decompression might be indicated. Early decompression is favorable for neural restitution.
In cases of secondary orbital reconstruction, a careful sharp dissection separating the infraorbital nerve from the orbital contents may be required.
In the pediatric patient the infraorbital nerve might exit closer to the infraorbital rim. The younger the patient, the closer to the rim.
The forced duction test should be performed to determine ocular motility as soon as general anesthesia is induced.
As soon as the periorbita has been dissected another forced duction test should be performed to determine ocular motility.
After the insertion of any implant material, it is imperative to perform a forced duction test to assure that the implant has not created a decrease in ocular motility.
Click here for details on the forced duction test.
The unique and complex anatomy of the orbit, unless prebent plates are used, requires significant contouring of the implants to restore the proper anatomy.
The majority of cases require reconstruction of the orbital floor to support the globe position and restore the shape of the orbit. The reason for this is that the bony walls are comminuted and/or bone fragments are missing. Therefore, one is reconstructing missing bone rather than reducing bone fragments. This can be accomplished using various materials. In large defects, preformed anatomic implants can help restore the complex internal orbital anatomy.
There is hardly any anatomic region in the human body that is so controversial in terms of appropriate material used for fracture repair:
Many surgeons recommend using materials that allow bending to an anatomical shape, that are radiopaque (to allow for intra- or postoperative radiologic confirmation of placement), and stable over time.
Reconstruction of the dislocated orbital walls is demanding. Secondary changes to this contour are undesirable. This is why critical consideration of the use of resorbable materials is necessary.
There are different preferences of implant material depending on regional differences, variations in schools of teaching, and socio-economic factors. There is a paucity of evidence to support the ideal choice for an orbital implant. Modern imaging analysis offers a unique chance to quantitatively asses the surgical result and stability over the time. This can provide valuable information for future recommendation.
Advantages:
Disadvantages:
Note: We do not have long term experience in a large series regarding the use of metallic mesh in young children. In several pediatric cases above the age of four it has proved to be safe.
Note: The extensive use of mesh for orbital reconstruction in traumatized orbits has been shown to be safe, with few problems due to infections and no problems with secondary displacement due to additional trauma, on condition of proper handling, contouring, and fixation of the mesh.
Illustration shows individual calvarial bone graft.
Advantages:
Disadvantages:
Advantages:
Disadvantages:
By combining titanium mesh with porous polyethylene the material becomes radiopaque, and more rigid than porous polyethylene of a similar thickness. Some surgeons also believe that there is less risk of having retained sharp barbs, which can lead to an entrapment of soft tissues during placement.
Advantages:
Disadvantages:
Thermoplastic and non-thermoplastic materials
Advantages:
Disadvantages:
Illustration showing a non-thermoplastic PDS sheet.
Advantages:
Disadvantages:
Multiplanar and 3-D view showing a preformed mesh plate placed prior to surgery into patient CT dataset.
Fixation of orbital reconstruction material varies with the type and nature of the fracture.
Fixation of most materials in the orbital floor is achieved by the use of one or more screws. The diameter depends on anatomical requirements but will normally vary between 1.0, 1.3, or 1.5 mm. Alternatively Matrix Midface screws can be used.
The orbital floor can be reached by various lower eyelid approaches (transcutaneous or transconjunctival).
Once the orbital floor is exposed, periorbital dissection is performed.
The following pages provide general information regarding orbital anatomy and dissection
Adequate exposure and illumination (headlights, illuminated retractors) of the fractured area is imperative prior to fixation.
Adequate hemostasis has to be achieved.
Appropriate retraction of the intraorbital soft tissues has to be performed.
A foil (or sheet of other material) may help with a retractor to avoid prolapse of soft tissues, to improve visualization, and prevent entrapment of soft tissues during implant placement.
The illustration shows the insertion of this foil below the retractor.
The retractor is then removed, placed under the foil, and the orbital soft tissues are properly retracted.
Note: Do not forget to remove the foil following implant placement.
This illustration shows the foil larger than the size of the retractor.
Helpful devices
Many different devices have been used to facilitate retraction of the orbital contents, including malleable retractors, spoons, and special orbital retractors designed for the globe (as illustrated).
A careful assessment of the defect size should be performed preoperatively with the CT scan in the sagittal view which is in the course of the orbital nerve, plus the coronal view showing the transverse extent.
It is crucial that in case of combined fracture types (eg, displaced zygoma fracture) the final defect size is only measured after proper repositioning of the outer frame. The defect size can be measured by the reading on the orbital retractor or any other instrument.
It is debated whether or not to extend the anterior part of the mesh over the infraorbital rim. Regardless of which fixation is placed over or posterior to the orbital rim, the overlying soft tissues must not be compromised in terms of form and function. Problems with the lower eyelid can be minimized by optimizing the fit, size, and thickness of the implant.
Note: special attention is paid to appropriate layered closure of the soft tissues overlying the inferior orbital rim allowing for resuspension of the soft tissue of the midface, and protection of the lower eyelid.
X-ray shows the extent of an orbital floor fracture in sagittal view.
Postoperative X-ray shows the S-shaped recontouring of the orbital floor.
The mesh is cut, …
… all sharp edges of the plate are trimmed off to protect the soft tissues (note the shape of the fan has only a minimum number of screw holes), …
… and contoured to achieve the required shape, and accommodate key anatomical structures (nasolacrimal duct, infraorbital nerve, and optic nerve)
It is advisable not to extend the implant further posterior than 1 cm anterior to the optic canal entrance (if the posterior support to the orbit can be reached).
A sterile artificial skull allows proper anatomical contouring of the implant. This is not required when using a prebent mesh.
Note:
Regardless of the implant chosen, the insertion process must prevent deformation of the mesh contour. Under adequate retraction of the intraorbital soft tissues the mesh has to be positioned so that proper and stable recontouring of the orbital walls results. Care has to be taken that neither orbital fat nor muscles are entrapped. During the insertion process, the mesh may require rotation in order to be properly positioned.
Additionally, navigation may serve for intraoperative control of implant or fragment position. Modern 3-D C-arm technology will furhter improve on intraoperative quality control of fracture reduction and implant positioning. Endoscopic modalities may be helpful in confirming proper implant placement.
If fixation is required, one screw will suffice in most cases. The screw can be placed into the floor of the orbit just posterior to the infraorbital rim. The screw size has to match the chosen mesh type.
Alternatively, the mesh can extend over the orbital rim and a screw can be placed on the anterior face of the maxilla.
After the insertion of any implant material, it is imperative to perform a forced duction test to assure that the implant has not created a decrease in ocular motility. Click here for details on the forced duction test.
Note: Pupils should be checked; however pupillary function might be compromised by drugs or mechanical force to the orbital contents.
If bone is harvested from a donor site, eg, cranial vault (parietal area), iliac crest, mandible, rib, etc. there may be donor site morbidity.
According to the dimension of the defect the bone has to be adapted and may be fixed either with screw fixation only or with plate and screw fixation (as illustrated).
Coronal slices (hard-tissue window) of an isolated left orbital floor fracture. Extensive intraorbital emphysema after the patient has blown his nose.
Sagittal slices (hard-tissue window) of an isolated left orbital floor fracture.
Transconjunctival incision and exposure of the fracture.
Repositioning of the fracture fragment.
Removal of displaced orbital floor.
An artificial skull is used intraoperatively to contour the plate in order to fit the shape of the orbit.
Bending of mesh to form …
… the bulges.
Checking the proper contour.
Exposure prior to mesh insertion.
Insertion of mesh.
Single screw fixation posterior to the orbital rim.
Postoperative sagittal slices of a cone beam CT of an isolated left orbital floor fracture treated with a fan-shaped titanium mesh.
Evaluation of the patients vision is performed as soon as they are awakened from anesthesia and then at regular intervals until they are discharged from the hospital.
A swinging flashlight test may serve in the unconscious and/or noncooperative patient; alternatively electrophysiological examination has to be performed but is dependent on the appropriate equipment (VEP).
Keeping the patient’s head in an upright position both preoperatively and postoperatively may significantly improve periorbital edema and pain.
To prevent orbital emphysema, nose-blowing should be avoided for at least 10 days following orbital fracture repair.
The use of the following perioperative medication is controversial. There is little evidence to make strong recommendations for postoperative care.
Postoperative examination by an ophthalmologist may be requested. The following signs and symptoms are usually evaluated:
Note: In case of postoperative double vision, ophthalmological assessment has to clarify the cause. Use of prism foils on existing glasses may be helpful as an early aid.
Postoperative imaging has to be performed within the first days after surgery. 3-D imaging (CT, cone beam) is recommended to assess complex fracture reductions. An exception may be made for centers capable of intraoperative imaging.
Especially in fractures involving the alveolar area, orthopantomograms (OPG) are helpful.
Remove sutures from skin after approximately 5 days if nonresorbable sutures have been used.
Apply ice packs (may be effective in a short term to minimize edema).
Avoid sun exposure and tanning to skin incisions for several months.
Diet depends on the fracture pattern.
Soft diet can be taken as tolerated until there has been adequate healing of the maxillary vestibular incision.
Intranasal feeding may be considered in cases with oral bone exposure and soft-tissue defects.
Clinical follow-up depends on the complexity of the surgery, and whether the patient has any postoperative problems.
With patients having fracture patterns including periorbital trauma, issues to consider are the following:
Other issues to consider are:
Issues to consider with Le Fort fractures, palatal fractures and alveolar ridge fractures include:
Following orbital fractures, eye movement exercises should be considered.
Implant removal is rarely required. It is possible that this may be requested by patients if the implant becomes palpable or visible. In some countries it will be more commonly requested. There have been cases where patients have complained of cold sensitivity in areas of plate placement. It is controversial whether this cold sensitivity is a result of the plate, a result of nerve injury from the original trauma, or from nerve injury due to trauma of the surgery. Issues of cold sensitivity generally improve or resolve with time without removal of the hardware.
Generally, orbital implant removal is not necessary except in the event of infection or exposure. Readmission might be indicated if long term stability of the orbital volume has not been maintained.
The patient needs to be examined and reassessed regularly and often. Additionally, ophthalmological, ENT, and neurological/neurosurgical examination may be necessary. If any clinical signs for meningitis or mental disturbances develop, professional help has to be sought. A regular follow-up CT scan is recommended 3-6 months after the trauma to assure proper pneumatization of the sinuses (particularly, mucocele formation has to be ruled out), sealing of the skull base and stability of fragment position.
Note: Posttrauma meningitis can occur even decades following trauma.
Travel in commercial airlines is permitted following orbital fractures. Commercial airlines pressurize their cabins. Mild pain on descent may be noticed. However, flying in military aircraft should be avoided for a minimum of six weeks.
No scuba diving should be permitted for at least six weeks.