In this procedure, compression of an extraarticular oblique fracture of the proximal phalangeal head with a lateral anatomical plate is shown (phalangeal head plate).
This follows the principles of compression plating of oblique fractures, ie, the plate should create an axilla (acute angle) with the oblique fracture line. If such an axilla cannot be created, dorsal plating or lag-screw fixation with a neutralization plate should be considered.
Depending on the fracture morphology and surgeon’s preference, compression can be applied in one of the following modes:
Obliquity of the fracture is possible either in the plane visible in the AP view or the lateral view. Always confirm the fracture configuration with views in both planes.
Two plate types are available for treatment of this fracture:
Select a plate according to fragment size, fracture geometry, and surgeon’s preference.
The plates are available as anatomical plates with variable-angle (VA) locking-head screws. This plate type has the advantage of sparing the soft tissue around the joints and allows insertion of two or three screws at variable angles into the articular block. The rounded plate edges avoid soft-tissue irritation and adhesion.
If an anatomical plate is not available, a conventional minicondylar plate may be used.
Place the patient supine with the arm on a radiolucent hand table.
For this procedure, the following approach may be used:
Reduction can be achieved by traction and lateral pressure exerted at the site of maximal displacement.
Confirm reduction clinically and with an image intensifier. If there is shortening of the finger, then there is often malrotation of the fracture.
If the fracture appears stable after reduction, nonoperative treatment can be considered. Confirming reduction with an image intensifier is then essential.
Sometimes indirect reduction may be prevented by interposition of the lateral band.
Direct reduction is necessary when the fracture cannot be reduced by traction and flexion or is unstable.
When indirect reduction is not possible, this is usually due to interposing parts of the extensor apparatus.
Use pointed reduction forceps for direct reduction.
Pointed reduction forceps, or a K-wire, may be used for preliminary fixation. However, in many cases, the position of the forceps, or the K-wire, will conflict with the planned plate or screw position.
For that reason, in many cases, the reduction is preliminarily held by an assistant holding the finger in flexion. If the extensor apparatus is intact, it will act as a tension band and hold the reduction.
At this stage, it is advisable to check the alignment and rotational correction by moving the finger through a range of motion.
Rotational alignment can only be judged with flexed metacarpophalangeal (MCP) joints. The fingertips should all point to the scaphoid.
Malrotation may manifest by an overlap of the flexed finger over its neighbor. Subtle rotational malalignments can often be judged by a tilt of the leading edge of the fingernail when the fingers are viewed end-on.
If the patient is conscious and the regional anesthesia still allows active movement, the patient can be asked to extend and flex the finger.
Any malrotation is corrected by direct manipulation and later fixed.
Under general anesthesia, the tenodesis effect is used, with the surgeon fully flexing the wrist to produce extension of the fingers and fully extending the wrist to cause flexion of the fingers.
Alternatively, the surgeon can exert pressure against the muscle bellies of the proximal forearm to cause passive flexion of the fingers.
The fixation of an oblique fracture with a dorsal plate follows the principles of compression plating of oblique fractures, ie, the plate should create an axilla with the oblique fracture line.
Adapt the plate length to fit the length of the proximal phalanx. Avoid sharp edges, which may be injurious to the tendons. There should be at least 3 plate holes proximal to the fracture available for fixation in the diaphysis. At least two screws need to be inserted into the diaphysis.
Place the plate slightly dorsal to the midaxial line of the bone, allowing at least two screws in the distal fragment.
To avoid conflict with the insertion of the collateral ligament, a K-wire may be placed in the isometric insertion of the collateral ligament and the notch of the plate aligned to it.
Keep the plate in place with the atraumatic forceps.
Introduction of a lag screw through the plate should be considered at this stage. The screw should run through the oblong hole and the middle of the fracture plane and as perpendicular as possible to it.
The screws are inserted in an order determined by the direction of the oblique fracture plane.
In our example, we will show an oblique fracture running from ulnar/proximal to radial/distal.
Insert at least two VA locking head screws in the articular block.
Insert the next screw in compression mode in the oblong hole.
Check the plate position with an image intensifier and adjust it if necessary.
Insert a planned lag screw through the oblong hole as perpendicularly to the fracture line as possible.
Insert further screws in the shaft and distal end.
Cover the plate with periosteum to avoid adhesion between the tendon and the implant leading to limited finger movement.
Confirm fracture reduction and stabilization and implant position with an image intensifier.
The aftercare can be divided into four phases of healing:
Full details on each phase can be found here.
If there is swelling, the hand is supported with a dorsal splint for a week. This would allow for finger movement and help with pain and edema control. The arm should be actively elevated to help reduce the swelling.
The hand should be splinted in an intrinsic plus (Edinburgh) position:
The reason for splinting the MCP joint in flexion is to maintain its collateral ligament at maximal length, avoiding scar contraction.
PIP joint extension in this position also maintains the length of the volar plate.
After subsided swelling, protect the digit with buddy strapping to a neighboring finger to neutralize lateral forces on the finger.
To prevent joint stiffness, the patient should be instructed to begin active motion (flexion and extension) immediately after surgery.
See the patient after 5 and 10 days of surgery.
The implants may need to be removed in cases of soft-tissue irritation.
In case of joint stiffness or tendon adhesion restricting finger movement, arthrolysis or tenolysis may become necessary. In these circumstances, the implants can be removed at the same time.