A NOE type II represents a comminuted fracture. The larger bone fragments need to be reduced and stabilized. This will often require 2- or 3-point fixation.
The canthal-bearing bone fragment requires exact repositioning.
The intercanthal distance should be restored.
In severely displaced bilateral NOE fractures the nasal projection should be restored by addressing nasal bone fractures and by adding bone graft if necessary.
Rule out CSF leak particularly in bilaterally displaced fractures in order to minimize the risk of early or delayed meningitis. Always make sure to rule out injuries to the eyes and the lacrimal apparatus.
Great care should be taken when considering placing plates anterior to the medial canthal ligament as these may be visible through the thin overlying skin.
Nasal bone involvement
If nasal bones are also fractured, they should be addressed and reduced. Fixation with plates may be necessary.
If the dorsum of the nose is comminuted or if can not be fully reduced, reconstruction with a cantilevered bone graft is performed.
Bilateral NOE fracture with nasal bone involvement
NOE type II fractures can occur bilaterally. A transnasal wiring may be necessary. A slight overcorrection of the intercanthal distance should be considered. The recommended intercanthal distance for white males is 33 to 34 mm and for white females 32 to 33 mm. Little data is available for other ethnic groups.
Numerous modalities may be used in order to hold the transnasal wire in the appropriate posterior position. These include the use of medial canthal plates, the use of mesh, which may be particularly desirable when the NOE fracture is combined with a medial orbital wall fracture, or the use of bone graft.
Transnasal wire
The transnasal wire technique may be necessary to properly reposition and fix the bone fragments.
The most common access for reduction of NOE fractures includes a combination of surgical approaches, that include a coronal, lower eyelid transcutaneous, lower eyelid tranconjunctival, and a maxillary vestibular incision. This combination of surgical approaches is often required to adequately visualize, reduce and stabilize extensively comminuted fractures. Additionally, the coronal approach may be useful in treating concomitant fractures of the frontal bone, nasal bones, zygomas, cranium, etc. It also provides access for harvesting calvarial bone grafts.
The glabellar approach alone does not allow enough exposure of a NOE type II fracture. The extended glabellar approach can be used with the maxillary vestibular approach in many cases.
In cases where there is a significant laceration over the nasal/NOE region this can often greatly facilitate the reduction of the NOE fractures.
NOE type II fractures can be difficult to reduce. The reasons for the difficulty could be the size of the fracture fragment as well as the poor direct access, requiring multiple surgical approaches.
While visualizing the reduction of the fractured segments through one surgical approach, the surgeon must continually recheck the reduction through the other surgical incisions. Some surgeons have used temporary plates or wires to stabilize the comminuted segments, prior to placement of the final plates.
NOE type II fractures represent a comminuted fracture where the medial canthus is still attached to a fragment of bone.
Commonly, a minimum of three points of fixation will be needed. This will include plating at the NOE/frontal bone (1), a plate along the orbital rim (2), and a plate along the piriform aperture (3). In addition to these plates, additional plates may be needed to further stabilize the comminuted fracture segments.
Order of fixation
A suggestion is to place the first plate where the surgeon has the best visualization and access, with the most well defined landmarks. If a surgeon has good visualization at all three points, a consideration is to first stabilize the NOE fracture to the frontal bone (1), achieving stabilization to the calvarium, with the second plate place along the orbital rim (2), and the third plate placed along the piriform aperture (3). This prioritizes plate placement according to the order of aesthetic importance.
In the illustrated case, the first plate is applied to the fracture between the NOE and the frontal bone through the coronal approach. (This can also be achieved through an extended glabellar approach.)
The second plate is then placed along the orbital rim through the inferior lid approach.
A third plate is placed along the piriform aperture through the maxillary vestibular approach.
In some cases the placement of a transnasal wire may be necessary in order to properly reduce and stabilize the fragment attached to the medial canthal tendon.
The transnasal wire needs to be placed before any other plates are put in. (The illustration shows the completed osteosynthesis.)
Via a coronal approach identify the bone fragment with the attached medial canthal tendon.
While holding the fragment with forceps, drill two holes in the bony fragment.
Pass the two ends of the wire through the two holes.
Depending on the stability of the bone in the NOE area the surgeon may need to drill a hole from the contralateral side, or use an awl to create a passage way. Many different techniques have been used to accomplish this. These include the use of a drill or a spinal needle. Extreme caution must be used to make sure that the spinal needle or drill bit does not advance too far, injuring the globe. It is important to use a malleable or spoon retractor to protect the globe.
While the spinal needle is still in place, the two ends of the wire are placed through the lumen of the needle, and both the spinal needle and wire are pulled out of the contralateral side of the NOE.
Alternative: using an awl
In this illustration an awl was first placed through the contralateral side, and then advanced to the side of the type II NOE fracture. The wire has been placed through the fragment attached to the medial canthus.
The two ends of the wire is then advanced to the contralateral side using the awl.
It is recommended that the surgeon perform a final check to confirm the correct position of the medial canthus.
Fix the fracture by plate application as previously described.
The transnasal wire is secured to a screw placed in the frontal bone, and tightened with the appropriate tension needed to secure the medial canthus into its proper position.
AP position of transnasal wire
NOE fractures often result in a lateral splaying of the medial canthi, resulting in telecanthus. This can often be corrected by placement of a transnasal wire.
When confronted with a NOE fracture requiring a transnasal wire, it is important to place the wire fixation in its proper posterior position. The upper illustration represents a wire that has been placed anteriorly, resulting in a further lateral splaying of the bone supporting the medial canthus, and a worsening of the telecanthus.
The lower illustration represents the proper posterior placement of the transnasal wire with a proper reduction of the bone attached to the medial canthus.
Horizontal position of transnasal wire
As much as the AP projection of the medial canthi is important, the horizontal position of the canthi is also very important.
In many cases the lateral canthi appear to be cephalad to a horizontal line through the medial canthi, while the eyelids are open. With the eyelids closed and in a more relaxed position, the lateral canthi fall into more of a horizontal position with the medial canthi. A surgeon should attempt to position the medial canthi into a relative horizontal line with the uninjured canthi.
In order to avoid an inferior malposition of the repaired medial canthal ligament many surgeons try to position the canthus as superiorly as possible.
A problem with NOE fractures is that even with a perfect bony reduction there may be a lack of definition in the medial canthal area (Epicanthal fold). Many surgeons advocate placing some sort of external nasal splints at the end of the procedure. If one chooses to use this technique, extreme caution is recommended. Patients will commonly have significant postoperative edema in this area, surgical incisions and lacerations can be present. If the splints are placed too tight, the patient is at risk of having skin necrosis in the medial canthal area.
This technique may be more relevant with the increased complexity of the NOE fracture. It may not be as applicable with a simple type I fracture where there has been minimal degloving of the soft tissues from the bone in the medial canthal area. It may be more beneficial in type II and type III fractures where there has been more comminution associated with a greater need for degloving of the soft tissues to achieve adequate reduction and fixation.
Some surgeons continue to use percutaneous bolsters to ensure adaptation of the skin to the underlying bone. However, these should be applied with great caution to avoid underlying skin necrosis.
Evaluation of the patient’s vision is performed as soon as they are awakened from anesthesia and then at regular intervals until they are discharged from the hospital.
A swinging flashlight test may serve in the unconscious and/or noncooperative patient; alternatively electrophysiological examination has to be performed but is dependent on the appropriate equipment visual evoked potential (VEP).
Keeping the patient’s head in a raised position both preoperatively and postoperatively may significantly improve edema and pain.
To prevent orbital emphysema, nose-blowing should be avoided for at least 10 days following NOE fracture repair.
The use of the following perioperative medication is controversial. There is little evidence to make strong recommendations for postoperative care.
Postoperative examination by an ophthalmologist may be requested. The following signs and symptoms are usually evaluated:
Note: In case of postoperative diplopia, ophthalmological assessment is needed to identify the cause. Hess-chart testing should be performed if diplopia persists.
Postoperative imaging has to be performed within the first days after surgery. 3-D imaging (CT, cone beam) is recommended to assess complex fracture reductions. In centers where intraoperative imaging is available postoperative imaging can be performed at a delayed time.
Remove sutures from skin after approximately 5 days if nonresorbable sutures have been used.
Apply ice packs (may be effective in a short term to minimize edema).
Avoid sun exposure and tanning to skin incisions for several months.
Diet depends on the fracture pattern and patients condition but there are usually no limitations.
Clinical follow-up depends on the complexity of the surgery, and the patient’s postoperative course.
In all patients with NOE trauma, all the following should be periodically assessed:
Other issues to consider are:
Implant removal is rarely required. It is possible that this may be requested by patients if the implant becomes palpable or visible. In some countries it will be more commonly requested. There have been cases where patients have complained of cold sensitivity in areas of plate placement. It is controversial whether this cold sensitivity is a result of the plate, a result of nerve injury from the original trauma, or from nerve injury due to trauma of the surgery. Issues of cold sensitivity generally improve or resolve with time without removal of the hardware.
Travel in pressurized aircraft is permitted 4 – 6 weeks postoperatively. Mild pain on descent may be noticed. However, flying in non-pressurized aircraft should be avoided for a minimum of 12 weeks.
No scuba diving should be permitted for at least 12 weeks. Additionally, the patient should be warned of long term potential risks.