1. Home
  2. Skeleton
  3. Diagnosis
  4. Indications
  5. Treatment

Screw fixation

1. General considerations

Partial articular fractures require anatomical reduction and may be fixed with lag screws if the size of the fragment allows.

The joint may collapse if there is impaction or comminution while the lag screw is tightened. In this case, plate fixation should be considered for subchondral support.

Proximal phalanx base partial articular fracture – screw fixation

Percutaneous vs open reduction and fixation

Percutaneous reduction and fixation may be performed with acute oblique fractures.

The advantage of a percutaneous reduction and fixation is:

  • Shorter operation time
  • Less soft-tissue damage
  • Faster mobilization

This treatment option needs some skills and experience and special reduction forceps to avoid impingement of swollen soft tissue (atraumatic technique).

If a percutaneous reduction is not achievable, the treatment can be changed to an open surgery.

Open reduction and fixation may be used in acute and delayed cases.

2. Patient preparation

This procedure is usually performed with the patient in a supine position with the arm on a radiolucent side table.

Patient in supine position with the arm on a side table

3. Approach

For this procedure, a dorsoulnar approach to the MCP joint can be used.

Skin incisions of a dorsoulnar approach to the MCP joint of the thumb

4. Reduction

Manipulate the articular fragment manually or with a dental pick, small K-wire, or a small periosteal elevator.

Small K-wires can also be used for preliminary fixation. Depending on fracture configuration, pointed forceps may be useful for reduction.

Application of excessive force can result in fragmentation.

Confirm reduction with an image intensifier.

Note: Anatomical reduction is important to prevent chronic instability or posttraumatic degenerative joint disease.
Proximal phalanx base partial articular fracture – reduction with pointed reduction forceps

Special reduction forceps designed for percutaneous fixation may be used to hold the reduction.

Proximal phalanx base partial articular fracture – reduction with Special reduction forceps designed for percutaneous fixation

Preliminarily fix the fragments by inserting a K-wire. Be careful to place it so it will not conflict with later screw placement.

Proximal phalanx base partial articular fracture – preliminary K-wire stabilization for screw fixation

Stability evaluation

Confirm reduction with an image intensifier and check the joint stability by flexion and extension. This should show congruent movement.

5. Checking alignment

Confirm correct rotational reduction by inspecting the thumb nail plate in relation to the index finger. Compare it to the contralateral side if necessary.

Checking correct rotational alignment of a fracture in the thumb by comparing the nail orientation with the uninjured thumb

6. Fixation

Planning for screw insertion

Each screw must be inserted perpendicularly to the fracture plane.

Do not insert screws too close to the fracture apex or the subchondral bone. A minimal distance from the fracture line, equal to the screw head diameter, must be observed.

The screw insertion should avoid conflicts with the MCP ligaments.

The screw length needs to be adequate for the screw to penetrate and purchase in the opposite (trans) cortex.

Proximal phalanx base partial articular fracture – planning the screw insertion

Screw size selection

The exact size of the diameter of the screws used will be determined by the fragment size and the fracture configuration.

Screw sizes of the diameters and thread hole drill sizes

Screw insertion

Insert the screw closest to the articular surface first.

Alternate tightening of the two lag screws helps to avoid tilting the fragment and applies even compression forces across the fracture surface.

Proximal phalanx base partial articular fracture – screw fixation
Pearl: To avoid rotation of the fragment during insertion of the first screw, use a K-wire in the trajectory of the second screw. This wire serves as an antirotation wire and creates the hole for the second screw at the same time.
Proximal phalanx base partial articular fracture – staged screw insertion to avoid rotation of fragment during drilling and screw insertion

In the next step, it is replaced with a screw.

Proximal phalanx base partial articular fracture – staged screw insertion to avoid rotation of fragment during drilling and screw insertion

7. Final assessment

Confirm anatomical reduction and fixation with an image intensifier.

8. Aftercare

Healing phases

The aftercare can be divided into four phases of healing:

  • Inflammatory phase (week 1–3)
  • Early repair phase (week 4–6)
  • Late repair and early tissue remodeling phase (week 7–12)
  • Remodeling and reintegration phase (week 13 onwards)

Full details on each healing phase can be found in the chapter Postoperative treatment of thumb injuries.

Postoperative care

Early range of motion, without load bearing, in the hand is important for optimal outcome.

Immediately postoperatively, a temporary plaster splint is applied. This also helps with swelling and pain control.

The plaster splint can be switched to a custom-made thermoplastic splint after a week. The splint should be worn until fracture healing has been confirmed.

Hand therapy should be initiated as soon as possible.

The arm should be actively elevated to help reduce any swelling.

Thumb spica splint including the IP joint of the thumb

Mobilization

To prevent joint stiffness, the patient should be instructed to begin active motion (flexion and extension) of all nonimmobilized joints of the hand immediately after surgery.

In compliant patients with stable fixation, the splint can be removed under the supervision of a hand therapist, and early active motion exercises started after a few days.

Weight bearing should be avoided until fracture healing is confirmed.

Functional exercises for mobilization of the hand

Follow-up

The surgical wound is checked as necessary depending on soft tissue status. The wound is monitored for evidence of infection.

To allow for early joint mobilization and to prevent wound dehiscence, leave the sutures for 2 weeks.

Confirm fracture healing clinically and radiologically after about 5–6 weeks (depending on the fracture configuration).