Bridge plating uses the plate as an extramedullary splint fixed to the two main fragments while the complex fracture zone is bridged.
The dissection required for anatomical reduction of all fragments would risk disturbing their blood supply and is not necessary. If the soft-tissue attachments of these fragments are preserved, and the fragments are relatively well aligned, healing is predictable.
It is important to restore axial alignment, length, and correct rotational alignment of the main shaft fragments.
Relative mechanical stability, provided by the bridging plate, leads to healing by callus formation.
The top end of the plate, eg, cross bar of a T-plate, may be applied dorsally on the distal or proximal fragment depending on the level of the fracture. The top end is usually placed on the shorter fracture fragment.
This procedure shows bridge plate fixation of a multifragmentary shaft fracture with a strut plate with VA locking-head screws.
The strut plate allows for more options to insert screws on both sides of the fracture zone. If anatomical fragment reduction is difficult to maintain, the plate may be used to guide fragment reduction. Fixation starts then at the bigger articular fragment.
For bridge plating, several plate types may be used:
The plates come with or without variable-angle (VA) and locking-head screws. For optimal bridging, especially to avoid shortening, locking screws should be used.
The plate selection depends on the fracture pattern and should allow at least two screws in the proximal and distal main fragments.
Usually, 1.3–1.5 mm plates are used for the fixation of the proximal phalanx.
This procedure is usually performed with the patient in a supine position with the arm on a radiolucent side table.
For this procedure, the following approach may be used:
Any axial displacement should be reduced to gain full length of the proximal phalanx.
Closed reduction is obtained by traction with extension of the IP joint, followed by dorsal pressure on the distal fragment and palmar pressure on the proximal fragment.
If the periosteum is intact, the small fragments of the comminution are brought into contact with the main fragments when the bone is brought out to length.
Confirm correct rotational reduction by inspecting the thumb nail plate in relation to the index finger. Compare it to the contralateral side if necessary.
The addition of bone graft or substitute is indicated to stabilize the fracture and avoid shortening, especially if a conventional plate with cortical screws has been selected.
The plate is positioned on the dorsal surface of the bone, aligned with the long axis.
Adapt the plate length to the length of the bone. Avoid sharp edges, which may be injurious to the tendons. There should be at least 3 plate holes proximal and distal to the fracture available for fixation in the diaphysis. At least two screws need to be inserted on each end.
Place the plate dorsally on the bone, as distally as possible, without interfering with the joint. The distal end of the plate should be proximal to the articular surface of the head.
Ensure that the plate is centered on the diaphysis in the coronal plane.
Keep the plate in place with K-wires.
Start with inserting a screw into each end of the plate:
Carefully drill the first screw hole. The drill bit should engage but not penetrate the far cortex.
Insert the first screw. Ensure that it engages the far cortex.
Ensure length and alignment (including rotation) of the distal fragment by imaging and visual examination. Readjust the plate position if necessary.
Insert subsequent screws in the same fashion into the main fragments according to fracture configuration.
Confirm correct rotational reduction by inspection of the thumb nail plate in relation to the index finger again.
Finalize screw insertion so that at least two screws are in both main fragments.
Cover the plate with periosteum, if possible, to avoid adhesion between the tendon and the implant leading to limited finger movement.
Confirm correct rotational alignment again.
Confirm reduction and correct placement of implants in AP, lateral, and oblique views.
The aftercare can be divided into four phases of healing:
Full details on each healing phase can be found in the chapter Postoperative treatment of thumb injuries.
Early range of motion, without load bearing, in the hand is important for optimal outcome.
Immediately postoperatively, a temporary plaster splint is applied. This also helps with swelling and pain control.
The plaster splint can be switched to a custom-made thermoplastic splint after a week. The splint should be worn until fracture healing has been confirmed.
Hand therapy should be initiated as soon as possible.
The arm should be actively elevated to help reduce any swelling.
To prevent joint stiffness, the patient should be instructed to begin active motion (flexion and extension) of all nonimmobilized joints of the hand immediately after surgery.
In compliant patients with stable fixation, the splint can be removed under the supervision of a hand therapist, and early active motion exercises started after a few days.
Weight bearing should be avoided until fracture healing is confirmed.
The surgical wound is checked as necessary depending on soft tissue status. The wound is monitored for evidence of infection.
To allow for early joint mobilization and to prevent wound dehiscence, leave the sutures for 2 weeks.
Confirm fracture healing clinically and radiologically after about 5–6 weeks (depending on the fracture configuration).
The implants may need to be removed in cases of soft-tissue irritation.
In case of joint stiffness or tendon adhesion restricting finger movement, arthrolysis or tenolysis may become necessary. In these circumstances, the implants can be removed at the same time.