Distal extraarticular fractures can be stabilized with metaphyseal support screws through a dorsal plate with a T-, Y- or an anatomical neck plate.
The focus of this construct lies in angular stabilization of the metacarpal head and less on fracture compression. It allows for plate placement proximal to the joint capsule.
Select a VA-locking plate (1.5-2.0 mm) according to the size of the bone, fracture geometry, and surgeon’s preference. A T-shaped plate may be used. Other shapes may also be applied.
A plate with variable-angle (VA) locking-head screws has the advantage to allow insertion of two or three screws in variable angles into the articular block. The rounded plate edges avoid soft-tissue irritation and adhesion.
This procedure is usually performed with the patient in a supine position with the arm on a radiolucent side table.
For this procedure, the following approach may be used:
Any axial displacement should be reduced to gain full length of the metacarpal.
Direct reduction is necessary when the fracture cannot be reduced by traction and flexion or is unstable.
Use two pointed reduction forceps for direct reduction.
In very unstable situations, insert a K-wire across the fracture plane for preliminary stabilization.
Be aware that the cortical bone in the metacarpal is dense and thick, so the K-wire tip gets very hot. Irrigation during K-wire insertion is essential to avoid thermal necrosis of the bone around the wire track.
Confirm reduction with an image intensifier and check the joint stability by flexion and extension. This should show congruent movement.
Confirm correct rotational reduction by inspecting the thumb nail plate in relation to the index finger. Compare it to the contralateral side if necessary.
Adapt the plate length to the length of the bone. Avoid sharp edges, which may be injurious to the tendons. There should be at least 3 plate holes proximal to the fracture available for fixation in the diaphysis. At least two screws need to be inserted into the diaphysis.
The plate has to be adapted accurately to the contour of the distal fragment. Use bending pliers to contour the plate. Be careful to bend in between the holes by positioning the pliers over the plate holes. Alternatively, insert the threaded bolt into the plate holes to bend the plate.
The bend should never go through a hole as this may damage the locking mechanism.
Place the plate proximal to the joint capsule on the dorsal aspect of the bone.
Hold the plate preliminarily with a cortical screw, not fully tightened, in the oblong hole. This allows for later adjustment of the plate position.
Insert two screws into the articular fragment through the T-end of the plate.
Drill carefully until the subchondral bone can be felt.
Confirm the reduction and correct metaphyseal support screw position using image intensification.
Insert the second and, if possible, a third screw into the proximal fragment and tighten them.
When the fixation is completed, remove any K-wire.
Cover the plate with periosteum, if possible, to avoid adhesion between the tendon and the implant leading to limited thumb movement.
Confirm correct rotational alignment by clinical examination.
Image intensification may be used to confirm anatomical reduction and correct placement of implants in two views.
The aftercare can be divided into four phases of healing:
Full details on each healing phase can be found in the chapter Postoperative treatment of thumb injuries.
Early range of motion, without load bearing, in the hand is important for optimal outcome.
Immediately postoperatively, a temporary plaster splint is applied. This also helps with swelling and pain control.
The plaster splint can be switched to a custom-made thermoplastic splint after a week. The splint should be worn until fracture healing has been confirmed.
Hand therapy should be initiated as soon as possible.
The arm should be actively elevated to help reduce any swelling.
To prevent joint stiffness, the patient should be instructed to begin active motion (flexion and extension) of all nonimmobilized joints of the hand immediately after surgery.
In compliant patients with stable fixation, the splint can be removed under the supervision of a hand therapist, and early active motion exercises started after a few days.
Weight bearing should be avoided until fracture healing is confirmed.
The surgical wound is checked as necessary depending on soft tissue status. The wound is monitored for evidence of infection.
To allow for early joint mobilization and to prevent wound dehiscence, leave the sutures for 2 weeks.
Confirm fracture healing clinically and radiologically after about 5–6 weeks (depending on the fracture configuration).
The implants may need to be removed in cases of soft-tissue irritation.
In case of joint stiffness or tendon adhesion restricting finger movement, arthrolysis or tenolysis may become necessary. In these circumstances, the implants can be removed at the same time.