1. Home
  2. Skeleton
  3. Diagnosis
  4. Indications
  5. Treatment

Lag-screw fixation

1. General considerations

Introduction

Treatment of long oblique and spiral fractures is similar. The difference is in the screw insertion in relation to the fracture plane, which is monoplanar in the long oblique fractures. In spiral fractures, the fracture plane is helical; therefore, each screw is inserted in a slightly different direction.

Indirect reduction is achieved by traction and digital manipulation. Usually, these fractures are unstable.

In a long fracture, fixation with two or more lag screws is usually sufficient, and a neutralization plate is not necessary.

Lag-screw fixation of a spiral and oblique shaft fracture of the thumb metacarpal

A good rule is the following: The fracture line (B) should be at least twice the length of the diameter of the metacarpal diaphysis (A), ie, B ≥ 2A for interfragmentary lag screws to provide sufficient fixation and stability.

Optimal fracture area for lag-screw fixation of an oblique shaft fracture of the thumb metacarpal

Fracture plane

Obliquity of the fracture is possible either in the plane visible in the AP view or the lateral view. Always confirm the fracture configuration with views in both planes.

Appearance of an oblique shaft fracture of the thumb metacarpal in different views

2. Patient preparation

This procedure is usually performed with the patient in a supine position with the arm on a radiolucent side table.

Patient in supine position with the arm on a side table

3. Approach

For this procedure, the following approach may be used:

Skin incisions of the dorsal approach to the thumb metacarpal

4. Reduction

Any axial displacement should be reduced to gain full length of the metacarpal. 

Pitfall: Axial malunion may lead to a Z-deformity with impact on grip and pinch functionality and painful hyperextension at the MCP joint and risk of arthrosis.
Axial malunion leading to a Z-deformity with impact on grip and pinch functionality and painful hyperextension at the MCP joint and risk of arthrosis

Visualizing the fracture

Rotate the finger and open the fracture for good direct visualization.

Determine the exact geometry of the fracture. This is very important for later screw placement.

Lag-screw fixation of a spiral shaft fracture of the thumb metacarpal – Rotation of the thumb for inspection of the fracture

Indirect reduction by traction

An assistant exerts traction while the surgeon reduces the fracture using pressure from a periosteal elevator or a dental pick.

Lag-screw fixation of a spiral shaft fracture of the thumb metacarpal - Traction of thumb for reduction of an oblique metacarpal fracture

Direct reduction

Gently use pointed reduction forceps to reduce the fracture anatomically.

Pitfall: Excessive pressure may cause fracture comminution.

Confirm reduction visually and with an image intensifier.

It is mandatory to confirm that the apex of each fracture fragment has been properly reduced; otherwise, malrotation may result.

Lag-screw fixation of a spiral shaft fracture of the thumb metacarpal – direct reduction with pointed reduction forceps

Preliminary fixation

Provisionally hold the reduction with either two K-wires or one K-wire and reduction forceps. Be careful to place them in such a way that they will not conflict with later screw placement.

Lag-screw fixation of a spiral shaft fracture of the thumb metacarpal – preliminary fracture stabilization with K-wires

5. Checking alignment

Confirm correct rotational reduction by inspecting the thumb nail plate in relation to the index finger. Compare it to the contralateral side if necessary.

Checking correct rotational alignment of a fracture in the thumb by comparing the nail orientation with the uninjured thumb

6. Screw fixation

Each lag screw must be inserted perpendicularly to the fracture plane.

In spiral fractures, the result is that the screws follow a helical disposition.

Note: Countersinking in the diaphysis should be performed with care as it risks iatrogenic fractures.
Lag-screw fixation of a spiral shaft fracture of the thumb metacarpal – Optimal screw orientation perpendicular to the fracture line

If the fracture length permits, insert three lag screws. Generally, they should be inserted at equal intervals.

Start with inserting the middle screw.

Lag-screw fixation of a spiral shaft fracture of the thumb metacarpal – Optimal distribution of screws along the fracture line

If the fragment is too short to allow for the insertion of three screws, use two screws, but recognize that this is a less stable construct. If in doubt, add a neutralization plate.

Insert both screws before fully tightening them.

Insert them as perpendicularly to the fracture plane as possible, either in an antegrade or retrograde fashion.

Lag-screw fixation of a spiral shaft fracture of the thumb metacarpal – Optimal distribution of screws along the fracture line

Screw-size selection

The exact size of the diameter of the screws used will be determined by the fragment size and the fracture configuration.

The various gliding and thread hole drill sizes for different screws are illustrated here.

Screw sizes of the diameters and thread hole drill sizes

Screw length pitfalls

Ensure that a screw of the correct length is used.
  • Too short screws do not have enough threads to engage the cortex properly. This problem increases when self-tapping screws are used due to the geometry of their tip.
  • Too long screws endanger soft tissues, especially tendons and neurovascular structures. With self-tapping screws, the cutting flutes are especially dangerous, and great care has to be taken that the flutes do not protrude beyond the cortical surface.
Correct screw length for bicortical fracture fixation means screws should not be too long or too short.

Pitfall: screw too close to the fracture

Do not insert screws too close to the fracture apex. A minimal distance from the fracture line, equal to the screw head diameter, should be observed if possible.
Screw placement not close to the fracture apex and with minimal distance to the fracture line equal to the diameter of the screw head

Pitfall: beware of fissure lines

Often there are short fissure lines that are not apparent on the x-rays. Check for these under direct vision and ensure the screws are not inserted through these fissure lines.
Screws inserted to avoid passing through short fissures

Pitfall: screw convergence

The screws should not converge to one point on the far cortex, as this may weaken the fixation if the holes are too close or if fissuring occurs when the screws are tightened. Such convergence will only occur if there is a failure to insert the screws perpendicular to the fracture plane.
In lag-screw fixation of an oblique metacarpal fracture, the screws should not converge to one point on the far cortex.

7. Final assessment

Confirm correct rotational alignment by clinical examination.

Image intensification may be used to confirm anatomical reduction and correct placement of implants in two views.

Lag-screw fixation of a spiral and oblique shaft fracture of the thumb metacarpal

8. Aftercare

Healing phases

The aftercare can be divided into four phases of healing:

  • Inflammatory phase (week 1–3)
  • Early repair phase (week 4–6)
  • Late repair and early tissue remodeling phase (week 7–12)
  • Remodeling and reintegration phase (week 13 onwards)

Full details on each healing phase can be found in the chapter Postoperative treatment of thumb injuries.

Postoperative care

Early range of motion, without load bearing, in the hand is important for optimal outcome.

Immediately postoperatively, a temporary plaster splint is applied. This also helps with swelling and pain control.

The plaster splint can be switched to a custom-made thermoplastic splint after a week. The splint should be worn until fracture healing has been confirmed.

Hand therapy should be initiated as soon as possible.

The arm should be actively elevated to help reduce any swelling.

Thumb spica splint immobilizing wrist, CMC, and MCP joints of the thumb and custom-made thermoplastic splint

Mobilization

To prevent joint stiffness, the patient should be instructed to begin active motion (flexion and extension) of all nonimmobilized joints of the hand immediately after surgery.

In compliant patients with stable fixation, the splint can be removed under the supervision of a hand therapist, and early active motion exercises started after a few days.

Weight bearing should be avoided until fracture healing is confirmed.

Functional exercises for mobilization of the hand

Follow-up

The surgical wound is checked as necessary depending on soft tissue status. The wound is monitored for evidence of infection.

To allow for early joint mobilization and to prevent wound dehiscence, leave the sutures for 2 weeks.

Confirm fracture healing clinically and radiologically after about 5–6 weeks (depending on the fracture configuration).