1. Home
  2. Skeleton
  3. Diagnosis
  4. Indications
  5. Treatment

Authors of section

Authors

Samy Bouaicha, Stefaan Nijs, Markus Scheibel, David Weatherby

Executive Editor

Simon Lambert

Open all credits

Revision of a reverse glenoid baseplate

1. Introduction

Periprosthetic glenoid fractures in cases of reverse glenoid baseplates can occur, either due to shear forces with incorrect component placement or due to long-standing and progressive lateral column scapula notching.

Traumatic periprosthetic glenoid fractures around reverse baseplate components are very rare, and usually occur after a fall.

A reverse glenoid baseplate

Preoperative planning

Preoperative planning should include the decision to consider:

  • Revision to another reverse or custom replacement
  • Conversion to a hemiarthroplasty
  • Conversion to an excision arthroplasty

An early sign of glenoid baseplate loosening is progressive notching involving the central peg or peripheral screws of the component. Additionally, notching of the lateral column of the scapula may occur.

The amount of glenoid bone loss is of tremendous importance to the revision strategy.

Modern revision planning software makes it possible to quantify the glenoid defect.

Preoperative CT planning is mandatory when deciding on a strategy of metallic (including augmented designs) or bony reconstruction.

Low-grade infection influences the decision-making process on whether a revision can be a one-stage or a two-stage procedure.

These principles are applicable for stemless, short, and standard stems.

Further details about prosthesis design can be found here.

A short stem configuration is shown in this description.

Stemless, short, and standard stems

2. Preparation

The standard patient position is the beach chair position with inclination of about 30°. An arm holder may be helpful but is not essential.

Intraoperative fluoroscopy can be helpful.

Patient positioning should be discussed with the anesthetist.

per 10 Pr110 Beach chair position at thirty degrees

Bone graft

If augmentation or reinforcement of the glenoid fracture or defect is required, bone allograft may be utilized. Structural bulk allograft or morselized allograft are indicated for specific conditions of the glenoid.

If allograft is not available be prepared to take cortico-cancellous or cancellous graft from the iliac crest (autograft) as shown.

Bone graft

The procedure is done under perioperative antibiotics.

Note: Antibiotics may be administered on induction of anesthetic without compromising the accuracy of microbiological diagnosis of soft-tissue biopsies.

3. Approach

The standard approach used is the deltopectoral approach, which can easily be extended proximally and distally.

Previous incisions should be used if this approach was performed correctly during the primary operation. Do not hesitate to perform a new skin incision if the approach used in the primary was inaccurate.

Deltopectoral approach

Soft-tissue management

Be prepared for extensive soft-tissue release and a more difficult subscapularis takedown technique before executing the arthrolysis needed to access the glenoid. Take biopsies for cultures.

In advanced chronic cases, metallosis, in the case of a central metal peg, or granulomatous synovial hypertrophy, in the case of a central polyethylene peg, may be present. A subtotal synovectomy is required in advanced stages.

4. Revision to a reverse implant

Revision of a reverse to a reverse component is possible in most cases.

Glenoid exposure and exchange

Remove the glenosphere and the baseplate component including the screws in order to expose the glenoid.
per 10 P340 Revision of a reverse glenoid baseplate

Management of the glenoid bone loss is closely related to the configuration of the remaining glenoid vault.

Management of the glenoid bone loss is closely related to the configuration of the remaining glenoid vault.

To facilitate stable fixation of a reverse baseplate, it may be necessary to reconstruct the glenoid vault using bone graft.

To facilitate stable fixation of a reverse baseplate, it may be necessary to reconstruct the glenoid vault using bone graft.

Glenoid reconstruction

Using bone – contained defects

In cases of mild glenoid contained defects (Type 1 according to Gohlke) impaction bone grafting is performed and a reverse base plate is implanted.

The illustration on the left is a representative cross section of the glenoid vault shown in the right diagram.

Case of mild glenoid contained defects (Type 1 according to Gohlke)

In cases of large, contained defects (Type 2) a structural allograft or autograft is impacted followed by implantation of the base plate.

Case of large, contained defects (Type 2 according to Gohlke)
Using bone – non-contained defects

In non-contained defects with either anterior or posterior wall insufficiency (Type 3) a structural allograft or autograft is used and fixed with two or three screws.

Case of non-contained defects with either anterior or posterior wall insufficiency (Type 3 according to Gohlke

In non-contained defects with severe medialization (Type 4) the same technique is applied.

The decision to perform a one versus two-stage base plate implantation depends on several factors:

  • Initial size of the defect
  • Primary stability of graft fixation
  • Specific implant features
  • Surgical experience
Non-contained defects with severe medialization (Type 4 according to Gohlke)

In all cases it is important to gain primary fixation in native bone. A reverse baseplate is shown with a central screw fixed into native bone with peripheral anti-rotation screws.

A reverse baseplate with a central screw fixed into native bone with peripheral anti-rotation screws.

In Type 5 defects with loss of the glenoid vault bony reconstruction should always be performed as a two-stage operation.

Custom implants are often required.

Defects with loss of the glenoid vault (Type 5 according to Gohlke)
Using metal

Off-the-shelf augmented base plates may be used in isolation or with bony reconstruction to achieve optimized fixation to the scapula.

Customized implants are not uniformly available and evidence for their role remains to be established.

Advantages include:

  • Single-stage procedure
  • Personalized to the patient and structural defect
  • Optimized function
  • Durability
  • Time zero structural support
  • No risk of graft reabsorption

Disadvantages include

  • Lack of availability
  • Cost
Off-the-shelf augmented base plates may be used in isolation (left) or with bony reconstruction (right)

A glenosphere is impacted on the baseplate.

A glenosphere is impacted on the baseplate

At the end of the procedure a trial component is used to check for stability. Then the final polyethylene liner is implanted, and the shoulder is reduced.

Shoulder reverse implant - final construct

5. Aftercare

Postoperative phases

The aftercare can be divided into four phases of healing:

  • Inflammatory phase (week 1–3)
  • Early repair phase (week 4–6)
  • Late repair and early tissue remodeling phase (week 7–12)
  • Remodeling and reintegration phase (week 13 onwards)

Full details on each phase can be found here.